Griffiths, P W; Norton, B; Eames, P C and Lo, S N G (1996) Detailed simulation of heat transfer across planar evacuated glazing. Building Research & Information, 24(3), pp. 141-147. ISSN 0961-3218
Abstract
In this paper techniques are described for modelling heat flow through evacuated glazing. Modelling results are compared with infra-red thermography. The centre of glass thermal performance of evacuated glazing is better than the performance of argon-filled, atmospheric pressure double glazings. Mitigation, or elimination of evacuated glazing edge effects will bring total window thermal performance on par, or better than, competing 'superwindow' options; thus increasing the commercial attractiveness of these glazings. The results of the computer-based thermal modelling at the Universities of Sydney and Ulster compare well with each other and with the infrared thermography measurements at Lawrence Berkeley.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | computer modelling; evacuated glazing; heat transfer; northern Ireland |
Date Deposited: | 11 Apr 2025 14:06 |
Last Modified: | 11 Apr 2025 14:06 |